전기 단층촬영법을 이용한 방광의 크기 추정
- Alternative Title
- Estimation of bladder size using EIT : Reconstruction performance analysis according to current injection pattern
- Abstract
- Dysuria which causes discomfort in daily life, needs to be continuously monitored for current bladder condition in order to diagnose, treat, or nurse patients after surgery. However, current clinical methods for monitoring bladder conditions are expensive, have difficulty in performing continuous monitoring, or are likely to cause complications.
EIT is an imaging modality that can monitor the internal state of the human body non-intrusively. In EIT, a small magnitude of electrical current is passed through the electrodes attached on the human body and measures the voltage between electrodes to visualize resistivitiy distribution inside the domain. EIT has many advantages compared to the other tomography techniques; It is not harmful to the human body. It has fast measurement speed so that temporal resolution is excellent and system design cost is low.
Therefore, the current bladder condition can be monitored non-invasively and continuously using EIT system.
The bladder is intertwined with the surrounding tissues, and is actually affected by the rectum, which is close to the bladder. Therefore, it is necessary to compare and analyze the performance of image reconstruction according to EIT modeling in order to reconstruct the bladder by generating the surrounding tissue. In the EIT method, the electrode number, width, position, and arrangement of electrodes should be considered during modeling.
Signal strength of the measured voltage data changes according to the injected current pattern through the electrodes, and affects image reconstruction performance.
In this paper, we compare the effect of current injection pattern and location of electrode array on reconstruction performance when EIT is applied to monitor three different sizes of bladder.
- Author(s)
- 韓侑庭
- Issued Date
- 2019
- Awarded Date
- 2019. 8
- Type
- Dissertation
- URI
- http://dcoll.jejunu.ac.kr/common/orgView/000000009034
- Alternative Author(s)
- Han, You Jung
- Affiliation
- 제주대학교 대학원
- Department
- 대학원 에너지응용시스템학부 전자공학전공
- Advisor
- Kim, Kyung Youn
- Table Of Contents
- 그림 목차 ⅱ
표 목차 ⅲ
초 록 ⅳ
제 1 장 서 론 1
제 2 장 전기 임피던스 단층촬영법 3
2.1 EIT의 물리적 모델 3
2.2 EIT의 정문제 해법 4
2.3 EIT의 역문제 해법 6
제 3 장 전기 임피던스 단층촬영법의 전류주입패턴 8
3.1 Adjacent 방법 8
3.2 Opposite방법 9
3.3 Trigonometric방법 9
3.4 Quasi-Adjacent방법 10
제 4 장 모의실험 및 실험 결과 12
4.1 16개의 전극을 균일하게 부착한 인체 하복부 영상복원 15
4.2 10개의 전극을 인체 하복부 앞쪽에 부착한 경우의 영상복원 25
제 5 장 결 론 35
참 고 문 헌 37
- Degree
- Master
- Publisher
- 제주대학교 대학원
- Citation
- 韓侑庭. (2019). 전기 단층촬영법을 이용한 방광의 크기 추정
-
Appears in Collections:
- Faculty of Applied Energy System > Electronic Engineering
- 공개 및 라이선스
-
- 파일 목록
-
Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.